# Peterhead fish processor fined £245,000 after worker's arm pulled into machine where guard was missing

> Lunar Freezing and Cold Storage Company Ltd pleaded guilty at Peterhead Sheriff Court after a chargehand was dragged into a rack loader through a gap left when a fixed guard was not replaced after maintenance.

Published 28 October 2026 by The Law Wire. Topic: Courts & cases. Canonical: https://lawwire.co.uk/story/peterhead-fish-processor-lunar-freezing-fined-245000-machine-guard

A Peterhead fish processing company was fined £245,000 at Peterhead Sheriff Court on 28 October after an employee's arm was pulled into a machine through a gap where a safety guard should have been, the [Health and Safety Executive](https://press.hse.gov.uk/2026/10/29/fish-processing-firm-fined-almost-a-quarter-of-a-million-pounds-after-workers-arm-pulled-into-machine-after-safety-guard-left-off/) said.

## What we know

- **The company:** Lunar Freezing and Cold Storage Company Ltd, of East Quay, The Harbour, Peterhead. It pleaded guilty and was also ordered to pay a victim surcharge of £18,375.
- **The incident:** on 19 August 2025 a 30-year-old chargehand went to clear a jammed box in a rack loader. He entered the line through a gap in the guarding without isolating the power and climbed onto the conveyor. The machine restarted, pulling his right arm into the pusher section, and his head struck moving parts before a colleague isolated the power.
- **Injuries:** a fractured jaw, which needed metal plates, and chest and arm trauma. He spent three days in Aberdeen Royal Infirmary, returned to work on 29 September 2025 and has made a full recovery.
- **What HSE found:** a section of fixed guarding had been removed during maintenance about two weeks earlier and not put back. Staff had used the gap to clear jams instead of an interlocked gate, and maintenance staff had seen this. The weekly inspection checklist did not cover non-electrical fixed guards.
- **The charges:** regulation 11(1) and (2) of the Provision and Use of Work Equipment Regulations 1998, and section 33(1)(c) of the Health and Safety at Work etc. Act 1974.

HSE inspector Nicky Smith called it "a wholly preventable incident", adding that checks "must cover every guard, not just the electrical ones" ([HSE](https://press.hse.gov.uk/2026/10/29/fish-processing-firm-fined-almost-a-quarter-of-a-million-pounds-after-workers-arm-pulled-into-machine-after-safety-guard-left-off/); see also [Food Manufacture](https://www.foodmanufacture.co.uk/Article/2026/10/30/scottish-fish-processor-fined-close-to-250k-after-mans-arm-pulled-into-machine/)).

The point for food and manufacturing clients is the gap in the inspection regime: a checklist that covered electrical safeguards but not fixed guards. A missing guard that staff knew about, and used, was enough for a six-figure fine even though the worker recovered fully.

## Sources

- [HSE — Fish processing firm fined almost a quarter of a million pounds after worker's arm pulled into machine after safety guard left off](https://press.hse.gov.uk/2026/10/29/fish-processing-firm-fined-almost-a-quarter-of-a-million-pounds-after-workers-arm-pulled-into-machine-after-safety-guard-left-off/)
- [Food Manufacture — Scottish fish processor fined almost £250K after worker pulled into machine](https://www.foodmanufacture.co.uk/Article/2026/10/30/scottish-fish-processor-fined-close-to-250k-after-mans-arm-pulled-into-machine/)